Skip to content

Lesson 3/10 · 17 words · 0 learned

Power distribution and switchgear

  1. 1

    fuse(noun)

    /fjuːz/

    a safety device with a thin wire that melts and breaks the circuit when too much current flows

    The control transformer fuse blew, so the panel had no power.

    Always replace a fuse with one of the same rating and type.

    Synonymscircuit breakercutoutprotective device
    Antonymsnone (in the same context)
  2. 2

    circuit breaker(noun)

    /ˈsɜːrkɪt breɪkər/

    a switch that opens automatically to stop the current when there is an overload or short circuit, and can be reset

    The circuit breaker tripped as soon as the compressor started.

    Unlike a fuse, a circuit breaker can be reset after the fault is cleared.

    Synonymsbreakerfusecutoff
    Antonymsconnectionfuse
  3. 3

    substation(noun)

    /ˈsʌbsteɪʃn/

    a site with transformers and switchgear where voltage is changed and power is distributed to local networks

    The industrial park takes power from a 110 kilovolt substation nearby.

    A fault at the substation caused a blackout across the district.

    SynonymsTransformer stationPower substation
    AntonymsNone
  4. 4

    three-phase(adjective)

    /'θri:,feiz/

    using three alternating currents of the same frequency, each timed differently, to supply power to heavy loads

    The workshop needs a three-phase supply for the large machines.

    Most industrial motors above three kilowatts are three-phase.

    Synonyms3-phasethree-phase power
    Antonymssingle-phase
  5. 5

    transformer(noun)

    /trænsˈfɔːrmər/

    a device that increases or reduces AC voltage using two or more coils of wire around an iron core

    A 22 kV to 0.4 kV transformer supplies the whole factory.

    Check the oil level and temperature of the transformer every week.

    Synonymsconverteradapterstep-up transformerstep-down transformer
    AntonymsN/A
  6. 6

    switchgear(noun)

    /ˈswɪtʃɡɪə(r)/

    the switches, breakers and fuses used to control, protect and isolate electrical equipment in a power system

    Only authorised staff may enter the medium-voltage switchgear room.

    The new switchgear has motorised breakers that can be operated remotely.

  7. 7

    main switchboard(noun)

    /ˌmeɪn ˈswɪtʃbɔːd/

    the main low-voltage panel that receives power from the transformer and distributes it to the building

    The main switchboard is fed directly from the 1,000 kVA transformer.

    Each outgoing feeder on the main switchboard has its own breaker.

  8. 8

    distribution board(noun)

    /ˌdɪstrɪˈbjuːʃn bɔːd/

    a panel that divides the supply into separate circuits, each protected by its own breaker or fuse

    Every floor has a distribution board for lighting and small power.

    Update the circuit chart inside the distribution board door.

  9. 9

    busbar(noun)

    /ˈbʌsbɑː(r)/

    a thick strip of copper or aluminium in a panel that carries large currents and connects several circuits

    Torque all busbar bolts to the value given by the manufacturer.

    The thermal camera showed a hot spot on the neutral busbar.

  10. 10

    MCB(abbreviation)

    /ˌem siː ˈbiː/

    miniature circuit breaker: a small breaker that protects final circuits such as lighting and sockets

    Replace the 16 amp MCB with a 20 amp one only if the cable allows it.

    Each lighting circuit is protected by its own MCB.

  11. 11

    MCCB(abbreviation)

    /ˌem siː siː ˈbiː/

    moulded case circuit breaker: a larger breaker with adjustable settings, used for feeders and big loads

    The chiller is fed from a 400 amp MCCB in the main switchboard.

    Set the MCCB trip current according to the coordination study.

  12. 12

    RCD(abbreviation)

    /ˌɑː siː ˈdiː/

    residual current device: a device that cuts the power quickly when current leaks to earth, protecting people from shock

    All socket circuits in wet areas must have 30 milliamp RCD protection.

    Press the test button on the RCD every three months.

  13. 13

    isolator(noun)

    /ˈaɪsəleɪtə(r)/

    a manual switch used to disconnect equipment completely from the supply so it can be worked on safely

    Turn off and lock the local isolator before opening the motor terminal box.

    Each air-conditioning unit has a weatherproof isolator next to it.

  14. 14

    neutral(noun)

    /ˈnjuːtrəl/

    the conductor that carries current back to the source, normally kept close to earth voltage

    A broken neutral can cause very high voltages on single-phase loads.

    Never share a neutral between circuits from different RCDs.

  15. 15

    load(noun)

    /ləʊd/

    the equipment that uses electricity in a circuit, or the amount of power it takes

    The total connected load of the building is about 800 kilowatts.

    Spread the load evenly so no single phase is overloaded.

  16. 16

    overload(noun)

    /ˈəʊvələʊd/

    a condition where a circuit or machine carries more current than it is designed for over a period of time

    The conveyor motor tripped on overload because the belt was jammed.

    Set the overload relay to the full-load current on the nameplate.

  17. 17

    surge protection device(noun)

    /ˈsɜːdʒ prəˌtekʃn dɪˌvaɪs/

    a device that limits sudden voltage spikes, for example from lightning, to protect equipment

    A surge protection device was fitted in the main board after the lightning damage.

    Check the status window on each surge protection device during inspections.