Pelajaran 2/10 · 16 kata · 0 sudah hafal
Wiring and installation
Pengawatan dan instalasi listrik
kabel
one or more insulated conductors inside a protective outer cover, used to carry electricity
We need to lay a 95 square millimetre cable from the transformer to the main board.
Kami perlu menarik kabel 95 milimeter persegi dari transformator ke panel utama.
Check the cable for cuts before pulling it through the conduit.
SinonimwirecordropestrandlineAntonimwirelesspemutusan hubungan kerja, PHK
the ending of an employment contract, by the employer, the employee or both sides
The termination of his contract takes effect at the end of the month.
Pemutusan hubungan kerjanya berlaku efektif pada akhir bulan.
HR must check the legal reasons for termination before sending the letter.
konduit, pipa pelindung kabel
a metal or plastic pipe that wires are pulled through to protect them
All wiring in the plant room must run in galvanised steel conduit.
Semua pengawatan di ruang mesin harus dipasang dalam konduit baja galvanis.
The electricians fixed the conduit to the ceiling before pulling the wires.
rak kabel, tray kabel
an open metal support, like a long shelf, used to carry and route many cables
The power cables and control cables run on separate cable trays.
Kabel daya dan kabel kontrol dipasang pada rak kabel yang terpisah.
Do not overload the cable tray; leave space for future cables.
talang kabel, trunking
an enclosed channel with a removable lid, fixed to walls or ceilings to hold cables
Put the lid back on the trunking after adding the new cables.
Pasang kembali tutup talang kabel setelah menambahkan kabel yang baru.
Surface trunking was used because the walls could not be chased.
kotak sambung, kotak percabangan
a small enclosed box where wires are joined or split into different circuits
All cable joints must be made inside an accessible junction box.
Semua sambungan kabel harus dibuat di dalam kotak sambung yang mudah dijangkau.
Use a waterproof junction box for the outdoor lighting.
stop kontak, soket keluaran
a device fixed to a wall or panel into which a plug is inserted to get power
Each workstation needs two socket outlets near the bench.
Setiap meja kerja membutuhkan dua stop kontak di dekat meja.
The socket outlet in the kitchen was scorched by a loose connection.
terminal blok, blok terminal, rel terminal
an insulated block with screw or spring clamps used to connect wires securely inside a panel
Land the field wires on the terminal block at the bottom of the panel.
Sambungkan kabel lapangan pada terminal blok di bagian bawah panel.
Each terminal block is numbered to match the wiring diagram.
kabel gland, glen kabel
a fitting that holds and seals a cable where it enters an enclosure or panel
Tighten the cable gland so dust and water cannot enter the motor box.
Kencangkan kabel gland agar debu dan air tidak dapat masuk ke kotak motor.
Armoured cables need a cable gland that also earths the armour.
sepatu kabel, lug kabel
a metal end fitting pressed onto a cable so it can be bolted to a terminal or busbar
Use the correct size cable lug for the 70 square millimetre conductor.
Gunakan sepatu kabel dengan ukuran yang tepat untuk penghantar 70 milimeter persegi.
The cable lug was loose, so the busbar connection overheated.
mengepres, mengrimping, mengeling
to join a connector or lug to a wire by squeezing it tightly with a special tool
Crimp the ferrule onto the wire before inserting it into the terminal.
Pres ferrule pada kawat sebelum memasukkannya ke terminal.
Badly crimped lugs are a common cause of hot joints.
luas penampang
the size of a conductor measured across its cut end, in square millimetres, which shows how much current it can carry
The cable's cross-sectional area must suit the load current and the cable length.
Luas penampang kabel harus sesuai dengan arus beban dan panjang kabel.
A 2.5 square millimetre cross-sectional area is typical for socket circuits.
jatuh tegangan, susut tegangan
the loss of voltage along a cable or component because of its resistance
On long cable runs, check the voltage drop does not exceed five percent.
Pada jalur kabel yang panjang, pastikan jatuh tegangan tidak melebihi lima persen.
The pump would not start because of a high voltage drop in the feeder.
selubung kabel, selubung luar
the outer protective layer of a cable that covers the insulated cores
The cable sheath was damaged where it rubbed against the steel beam.
Selubung kabel rusak pada bagian yang bergesekan dengan balok baja.
Keep the outer sheath inside the gland so no bare cores are visible.