Lección 10/10 · 15 palabras · 0 aprendidas
Electrical safety
Seguridad eléctrica
descarga eléctrica, electrocución
the injury or sudden pain caused when electric current passes through a person's body
He received an electric shock from a damaged extension lead.
Recibió una descarga eléctrica de una extensión dañada.
RCDs greatly reduce the risk of a fatal electric shock.
Sinónimoselectrical shockelectrocutionjoltAntónimosnoneelectrocución
death or serious injury caused by electric current passing through the body
Working near overhead lines without a permit risks electrocution.
Trabajar cerca de líneas aéreas sin un permiso conlleva riesgo de electrocución.
The investigation found that the electrocution was caused by a missing earth.
Sinónimoselectric shockelectrocutionAntónimosrevivalresuscitationbloqueo y etiquetado, LOTO
a safety procedure where a machine's energy sources are switched off, locked and tagged before maintenance work
Apply lockout/tagout before you put your hands inside the machine.
Aplique el bloqueo y etiquetado antes de meter las manos dentro de la máquina.
Every maintenance technician has a personal lock for lockout/tagout.
SinónimosControl of Hazardous EnergyEnergy IsolationAntónimosActivationEnergizationpuesta a tierra, conexión a tierra
connecting metal parts of an installation to the ground so that fault current flows safely away
Good earthing makes sure the breaker trips quickly during a fault.
Una buena puesta a tierra asegura que el interruptor automático se dispare rápidamente durante una falla.
Check the earthing of all metal cable trays before handover.
conexión equipotencial, unión equipotencial
connecting exposed metal parts and pipes together so they stay at the same voltage and cannot cause a shock
Equipotential bonding is required for the water and gas pipes.
Se requiere conexión equipotencial para las tuberías de agua y de gas.
The bathroom failed inspection because the equipotential bonding was missing.
energizado, con tensión
connected to a source of electricity and able to give a shock
Treat every conductor as live until you have tested it.
Trate todos los conductores como energizados hasta que los haya comprobado.
Live working is allowed only with a special permit and trained staff.
desenergizar, cortar la energía
to disconnect equipment or a circuit from its power supply so that it is no longer live
De-energise the panel and prove it dead before removing any covers.
Desenergice el tablero y compruebe la ausencia de tensión antes de retirar cualquier cubierta.
The feeder was de-energised for six hours during the maintenance work.
aislamiento seguro, bloqueo y etiquetado
the procedure of switching off, locking off and testing equipment to prove it is dead before work starts
Follow the safe isolation procedure before working on any circuit.
Siga el procedimiento de aislamiento seguro antes de trabajar en cualquier circuito.
Safe isolation includes testing your voltage tester on a known live source.
permiso de trabajo
a written approval that states what work may be done, the hazards and the safety steps that must be taken
No one may open the switchgear without a signed permit to work.
Nadie puede abrir el tablero de distribución sin un permiso de trabajo firmado.
The permit to work lists the isolation points and earthing locations.
arco eléctrico, destello de arco
a sudden explosion of heat and light caused by a fault current jumping through the air between conductors
Wear an arc flash suit when racking out the breaker.
Use un traje contra arco eléctrico al extraer el interruptor automático.
An arc flash can cause severe burns even several metres away.
guantes dieléctricos, guantes aislantes
rubber gloves rated for a certain voltage that protect the hands from electric shock
Inspect your insulated gloves for holes before every use.
Revise sus guantes dieléctricos en busca de agujeros antes de cada uso.
Insulated gloves must be tested in a lab every six months.
alta tensión, alto voltaje
voltage high enough to need special equipment and training, usually above 1,000 volts AC
Only authorised persons may work on high voltage equipment.
Solo el personal autorizado puede trabajar en equipos de alta tensión.
Danger signs warn of high voltage on the transformer fence.
baja tensión, bajo voltaje
voltage used in ordinary buildings and machines, usually up to 1,000 volts AC
The low voltage side of the transformer supplies the main switchboard.
El lado de baja tensión del transformador alimenta el tablero principal.
She is qualified to work on low voltage installations up to 1,000 volts.
doble aislamiento
a design with two layers of insulation so that a tool or appliance needs no earth connection
Power tools with double insulation have a square-in-a-square symbol.
Las herramientas eléctricas con doble aislamiento llevan el símbolo de un cuadrado dentro de otro cuadrado.
Double insulation protects the user even if one layer fails.
fuga a tierra, corriente de fuga
a small current that flows to earth through damaged insulation instead of returning through the neutral
Moisture in the cable caused earth leakage and tripped the RCD.
La humedad en el cable provocó una fuga a tierra y disparó el interruptor diferencial.
The earth leakage relay alarms at 300 milliamps on the main feeder.