Measurement and fault finding
Medição e localização de falhas
calibrar, aferir
to check and adjust a measuring instrument so that its readings are accurate
All test instruments must be calibrated once a year.
Todos os instrumentos de teste devem ser calibrados uma vez por ano.
The pressure transmitter was calibrated before the system was started.
SinônimosadjusttunecorrectstandardizesetAntônimosunbalancemisadjustdistortosciloscópio
an instrument that shows how a voltage changes over time as a waveform on a screen
The oscilloscope showed noise on the encoder signal.
O osciloscópio mostrou ruído no sinal do encoder.
Use an isolated oscilloscope probe when measuring the drive output.
Sinônimosscopewaveform monitorAntônimosN/Adiagnosticar e resolver problemas, solucionar problemas
to find the cause of a technical problem and fix it, usually by checking possible causes one by one
The technician spent an hour troubleshooting the Wi-Fi in the meeting room.
O técnico passou uma hora solucionando problemas do Wi-Fi da sala de reuniões.
Follow these steps to troubleshoot common login problems.
SinônimosdiagnosefixresolvedebugAntônimosignoreneglectmultímetro
a handheld meter that measures voltage, current and resistance, and can test continuity
Set the multimeter to AC volts before checking the socket.
Ajuste o multímetro para volts CA antes de verificar a tomada.
Every technician carries a digital multimeter in the tool bag.
alicate amperímetro
a meter with jaws that close around a single wire to measure current without disconnecting it
Use a clamp meter to check the current on each phase of the motor.
Use um alicate amperímetro para verificar a corrente em cada fase do motor.
Clamp only one conductor, or the clamp meter will read zero.
megôhmetro, medidor de resistência de isolamento
an instrument that applies a high test voltage to measure how well cable or winding insulation prevents leakage
Test the motor with an insulation resistance tester at 500 volts.
Teste o motor com um megôhmetro a 500 volts.
Disconnect the electronics before using the insulation resistance tester on the cable.
terrômetro, medidor de resistência de aterramento
an instrument used to measure the resistance between an earth electrode and the surrounding ground
The earth resistance tester showed 2 ohms, which meets the requirement.
O terrômetro indicou 2 ohms, o que atende ao requisito.
Drive the test spikes into the soil before using the earth resistance tester.
ponta de prova, cabo de teste
an insulated wire with a probe or clip that connects a meter to the circuit being measured
Replace any test lead with cracked insulation before you use the meter.
Substitua qualquer ponta de prova com isolação rachada antes de usar o medidor.
Plug the red test lead into the volts socket of the meter.
teste de continuidade
a test that checks whether a conductor or circuit forms a complete path with no breaks
Do a continuity test on the earth conductor before energising the board.
Faça um teste de continuidade no condutor de aterramento antes de energizar o quadro.
The continuity test showed a broken wire inside the trailing cable.
termografia, inspeção termográfica
the use of a special camera that shows heat, to find hot connections and overloaded parts
A thermal imaging survey found three loose busbar joints.
Uma inspeção termográfica encontrou três juntas soltas nos barramentos.
We do thermal imaging of all main panels every six months.
comissionamento
the process of testing and checking new electrical equipment to prove it works correctly before handover
Commissioning of the new switchboard is planned for next Tuesday.
O comissionamento do novo quadro de distribuição está previsto para a próxima terça-feira.
All test results must be recorded in the commissioning report.
falta à terra, fuga para a terra
a fault where a live conductor accidentally touches earth or a metal part connected to earth
An earth fault in the outdoor light tripped the RCD.
Uma falta à terra na luminária externa fez o DR desarmar.
The relay detected an earth fault on feeder number four.
desarmar, atuar
of a breaker or protection device: to switch off automatically because it detects a fault or overload
The RCD in the outdoor lighting board keeps tripping whenever it rains.
O DR do quadro de iluminação externa fica desarmando sempre que chove.
The overload relay tripped because the pump was blocked.
mau contato, conexão frouxa
a terminal or joint that is not tight, which can cause heat, sparking or an intermittent fault
A loose connection at the terminal caused the cable to burn.
Um mau contato no terminal fez o cabo queimar.
Most intermittent faults in panels are caused by a loose connection.