Skip to content

Lesson 9/10 · 15 words · 0 learned

Measurement and fault finding

  1. 1

    calibrate(verb)

    /ˈkælɪbreɪt/

    to check and adjust a measuring instrument so that its readings are accurate

    All test instruments must be calibrated once a year.

    The pressure transmitter was calibrated before the system was started.

    Synonymsadjusttunecorrectstandardizeset
    Antonymsunbalancemisadjustdistort
  2. 2

    oscilloscope(noun)

    /əˈsɪləskəʊp/

    an instrument that shows how a voltage changes over time as a waveform on a screen

    The oscilloscope showed noise on the encoder signal.

    Use an isolated oscilloscope probe when measuring the drive output.

    Synonymsscopewaveform monitor
    AntonymsN/A
  3. 3

    troubleshoot(verb)

    /ˈtrʌblʃuːt/

    to find the cause of a technical problem and fix it, usually by checking possible causes one by one

    The technician spent an hour troubleshooting the Wi-Fi in the meeting room.

    Follow these steps to troubleshoot common login problems.

    Synonymsdiagnosefixresolvedebug
    Antonymsignoreneglect
  4. 4

    multimeter(noun)

    /ˈmʌltimiːtə(r)/

    a handheld meter that measures voltage, current and resistance, and can test continuity

    Set the multimeter to AC volts before checking the socket.

    Every technician carries a digital multimeter in the tool bag.

  5. 5

    clamp meter(noun)

    /ˈklæmp ˌmiːtə(r)/

    a meter with jaws that close around a single wire to measure current without disconnecting it

    Use a clamp meter to check the current on each phase of the motor.

    Clamp only one conductor, or the clamp meter will read zero.

  6. 6

    insulation resistance tester(noun)

    /ˌɪnsjuˈleɪʃn rɪˈzɪstəns ˌtestə(r)/

    an instrument that applies a high test voltage to measure how well cable or winding insulation prevents leakage

    Test the motor with an insulation resistance tester at 500 volts.

    Disconnect the electronics before using the insulation resistance tester on the cable.

  7. 7

    earth resistance tester(noun)

    /ˈɜːθ rɪˌzɪstəns ˌtestə(r)/

    an instrument used to measure the resistance between an earth electrode and the surrounding ground

    The earth resistance tester showed 2 ohms, which meets the requirement.

    Drive the test spikes into the soil before using the earth resistance tester.

  8. 8

    test lead(noun)

    /ˈtest liːd/

    an insulated wire with a probe or clip that connects a meter to the circuit being measured

    Replace any test lead with cracked insulation before you use the meter.

    Plug the red test lead into the volts socket of the meter.

  9. 9

    continuity test(noun)

    /ˌkɒntɪˈnjuːəti test/

    a test that checks whether a conductor or circuit forms a complete path with no breaks

    Do a continuity test on the earth conductor before energising the board.

    The continuity test showed a broken wire inside the trailing cable.

  10. 10

    thermal imaging(noun)

    /ˌθɜːml ˈɪmɪdʒɪŋ/

    the use of a special camera that shows heat, to find hot connections and overloaded parts

    A thermal imaging survey found three loose busbar joints.

    We do thermal imaging of all main panels every six months.

  11. 11

    commissioning(noun)

    /kəˈmɪʃənɪŋ/

    the process of testing and checking new electrical equipment to prove it works correctly before handover

    Commissioning of the new switchboard is planned for next Tuesday.

    All test results must be recorded in the commissioning report.

  12. 12

    fault(noun)

    /fɔːlt/

    a defect or abnormal condition in an electrical circuit or device that stops it working correctly

    The breaker opened to isolate the fault in the cable.

    Write the fault and the repair in the maintenance log.

  13. 13

    earth fault(noun)

    /ˈɜːθ fɔːlt/

    a fault where a live conductor accidentally touches earth or a metal part connected to earth

    An earth fault in the outdoor light tripped the RCD.

    The relay detected an earth fault on feeder number four.

  14. 14

    trip(verb)

    /trɪp/

    of a breaker or protection device: to switch off automatically because it detects a fault or overload

    The RCD in the outdoor lighting board keeps tripping whenever it rains.

    The overload relay tripped because the pump was blocked.

  15. 15

    loose connection(noun)

    /ˌluːs kəˈnekʃn/

    a terminal or joint that is not tight, which can cause heat, sparking or an intermittent fault

    A loose connection at the terminal caused the cable to burn.

    Most intermittent faults in panels are caused by a loose connection.