تخطَّ إلى المحتوى

الدرس 8/10 · 15 كلمة · تم تعلّم 0

Measurement and inspection

القياس والفحص

  1. 1

    accuracy(noun)

    /ˈækjərəsi/

    الدقة

    how close a measurement or result is to the true or correct value

    The accuracy of the new machine is within 5 microns.

    دقة الآلة الجديدة ضمن 5 ميكرونات.

    Temperature changes can affect the accuracy of your measurements.

    المرادفاتprecisioncorrectnessexactnesstruthfulnessvalidityreliability
    الأضدادinaccuracyerrorimprecisionfalsenessincorrectness
  2. 2

    precision(noun)

    /prɪˈsɪʒn/

    الدقة, الضبط

    how close repeated measurements or results are to each other; also the quality of being very exact

    The company makes precision parts for medical devices.

    تصنّع الشركة قطعًا عالية الدقة للأجهزة الطبية.

    Good precision means you get the same reading every time.

    المرادفاتaccuracyexactnessfinenesscarefulnessmeticulousness
    الأضدادimprecisioninaccuracycarelessnessvaguenessindefiniteness
  3. 3

    calibration(noun)

    /ˌkælɪˈbreɪʃn/

    معايرة

    checking a measuring instrument against a known standard and adjusting it so its readings are correct

    This caliper is overdue for calibration, so do not use it.

    حان موعد معايرة هذا الفرجار منذ مدة، لذا لا تستخدمه.

    Every gauge has a calibration label showing the next due date.

    المرادفاتadjustmentstandardizationtuningcorrection
    الأضدادmisalignmentinaccuracyerror
  4. 4

    vernier caliper(noun)

    /ˈvɜːniə ˌkælɪpə(r)/

    قدمة ذات ورنية, ميكرومتر, بياكوليس

    a sliding measuring tool with jaws, used to measure outside, inside and depth sizes accurately

    Measure the outside diameter with a vernier caliper.

    قِس القطر الخارجي بالقدمة ذات الورنية.

    A vernier caliper is accurate to about 0.02 millimetres.

  5. 5

    micrometer(noun)

    /maɪˈkrɒmɪtə(r)/

    ميكرومتر, ميكرومتر القياس

    a precise measuring tool with a screw mechanism, used to measure small sizes to 0.01 mm or better

    Use a micrometer to check the bearing seat diameter.

    استخدم الميكرومتر لفحص قطر مقعد المحمل.

    Always zero the micrometer before you start measuring a part.

  6. 6

    dial indicator(noun)

    /ˈdaɪəl ɪndɪkeɪtə(r)/

    مؤشر ذو ميناء, مقياس ساعة قياس, ساعة القياس

    a measuring instrument with a needle and dial that shows very small movements, such as runout

    Check the shaft runout with a dial indicator on a magnetic base.

    افحص الانحراف الدوراني للعمود بمؤشر ذي ميناء مثبت على قاعدة مغناطيسية.

    The dial indicator showed 0.05 mm of movement on the spindle.

  7. 7

    feeler gauge(noun)

    /ˈfiːlə ɡeɪdʒ/

    مقياس الفجوات, مقياس السماكة, فيلر

    a set of thin metal blades of exact thicknesses, used to measure small gaps

    Measure the gap between the coupling halves with a feeler gauge.

    قِس الفجوة بين نصفي الوصلة بمقياس الفجوات.

    The valve clearance is checked with a 0.2 mm feeler gauge.

  8. 8

    gauge block(noun)

    /ˈɡeɪdʒ blɒk/

    كتلة قياس معيارية, قالب قياس معياري, بلوكة قياس

    a very accurate steel or ceramic block of exact size, used as a reference to check measuring tools

    We check our micrometers against a gauge block every week.

    نفحص الميكرومترات لدينا بمقارنتها بكتلة قياس معيارية كل أسبوع.

    Handle gauge blocks with gloves to avoid rust from your fingers.

  9. 9

    go/no-go gauge(noun)

    /ˌɡəʊ nəʊ ˈɡəʊ ɡeɪdʒ/

    مقياس يمر/لا يمر, مقياس حدّي

    a gauge with two ends that quickly shows whether a hole or thread is within its size limits

    Operators check every tapped hole with a go/no-go gauge.

    يفحص العاملون كل ثقب مسنَّن بواسطة مقياس يمر/لا يمر.

    If the no-go end enters the hole, the part is rejected.

  10. 10

    surface plate(noun)

    /ˈsɜːfɪs pleɪt/

    منضدة مرجعية مسطحة, طاولة سطح مرجعي

    a very flat granite or cast iron table used as a reference surface for measuring and marking out

    Place the part on the surface plate to check its flatness.

    ضع القطعة على المنضدة المرجعية للتحقق من استوائها.

    The granite surface plate is calibrated once a year.

  11. 11

    CMM(abbreviation)

    /ˌsiː em ˈem/

    آلة قياس الإحداثيات, CMM

    coordinate measuring machine: a machine with a probe that measures the exact 3D shape and size of parts

    The first part off the machine is measured on the CMM.

    تُقاس أول قطعة تخرج من الماكينة على آلة قياس الإحداثيات.

    The CMM report shows two holes out of position.

  12. 12

    first article inspection(noun)

    /ˌfɜːst ˈɑːtɪkl ɪnspekʃn/

    فحص القطعة الأولى, فحص العينة الأولى

    a full check of the first part made in a new production run to confirm it meets the drawing

    Production cannot start until the first article inspection is approved.

    لا يمكن بدء الإنتاج قبل اعتماد فحص القطعة الأولى.

    The customer asked for a first article inspection report with every new part.

  13. 13

    NDT(abbreviation)

    /ˌen diː ˈtiː/

    الفحص غير الإتلافي, NDT

    non-destructive testing: methods of checking materials and welds for hidden defects without damaging them

    All pressure welds must pass NDT before the vessel is painted.

    يجب أن تجتاز جميع لحامات الضغط الفحص غير الإتلافي قبل طلاء الوعاء.

    An NDT technician will check the crane hook for cracks.

  14. 14

    ultrasonic testing(noun)

    /ˌʌltrəˈsɒnɪk testɪŋ/

    الفحص بالموجات فوق الصوتية

    an NDT method that sends high-frequency sound waves into metal to find cracks or measure thickness

    Ultrasonic testing found a crack inside the shaft.

    كشف الفحص بالموجات فوق الصوتية عن شق داخل العمود.

    We use ultrasonic testing to measure the remaining wall thickness of pipes.

  15. 15

    dye penetrant testing(noun)

    /ˌdaɪ ˈpenɪtrənt testɪŋ/

    الفحص بالسوائل النافذة, الفحص بالصبغة النافذة

    an NDT method where a coloured liquid is put on a surface to show small cracks that reach the surface

    Dye penetrant testing showed a hairline crack at the weld toe.

    أظهر الفحص بالسوائل النافذة شقًا شعريًا عند حافة اللحام.

    Clean the surface well before dye penetrant testing.